Documentation
Certifications & Documents
The stamped documents behind the ATRIA system — CE declarations, antibacterial test reports, the HACCP test report, and safety data sheets. Every test figure carries its report number, and every document is downloadable in full.
CE Declarations — EU Construction Products Regulation 305/2011
Colorificio Atria S.r.l. (Partanna, Sicily) issues CE Declarations of Conformity and Declarations of Performance for the four components of the ATRIA microcement system under EU Regulation No. 305/2011. Each download contains the stamped original and its English translation; the declared performance values below are transcribed from the Declarations of Performance.
Atriafloor Consolidante
Two-component water-dilutable consolidating epoxy primer
Issued 23 April 2025
DoC + DoPAtriafloor Rasante One
True Cement two-component cementitious base coat
- Compressive strength 42 ± 2 MPa at 28 days (EN 1015-11)
- Flexural strength 3.2 ± 2 MPa at 28 days (EN 1015-11)
- Adhesion > 2.2–2.5 MPa after 7 days (UNI 8298-1)
Issued 23 April 2025
DoC + DoPSuper Titanium BC
Two-component decorative coating based on polyurethane resins, interior walls and floors
- Compressive strength 32 ± 2 MPa at 28 days (EN 1015-11)
- Flexural strength 3.5 ± 2 MPa at 28 days (EN 1015-11)
- Adhesion > 3–3.5 MPa after 7 days (UNI 8298-1)
- Pull-off adhesion > 2.5 N/mm² (ASTM D4541)
- Hardness Shore D5 > 65 (DIN 53505)
Issued 23 April 2025
DoC + DoPNew Atriapol Antibacterial
Two-component clear polyurethane UV-resistant protective finish
- Abrasion resistance > 60 mg after 7 days (Taber 1,000 g / 1,000 rev, EN ISO 5470-1)
- Direct adhesion > 3.6 MPa — rigid system under wheeled traffic (EN 1542)
- Capillary water absorption 0.052 kg/m²·h⁰·⁵ (EN 1062)
- Hardness Shore D5 > 60 (DIN 53505)
Issued 2 April 2025
DoC + DoPAntibacterial activity — ISO 22196:2011
Antibacterial activity measured to ISO 22196:2011 by 3A Laboratori S.r.l., Maserà di Padova (LAB N° 1165 L) — five test reports issued 1 June 2020 to Colorificio Atria S.r.l. The tested sample is described in the reports as the manufacturer's “AntiBacterical” washable water-based antibacterial paint; the manufacturer declares this HACCP / ISO 22196:2011 certification on New Atriapol Antibacterial, the protective finish of the ATRIA microcement system (see its CE declaration above). Measured activity across the six organisms tested:
| Organism | Type | Activity (R) | Reduction | Report No. |
|---|---|---|---|---|
| Escherichia coli | Gram − | > 5.1 | > 99.999% | 20LA05883 |
| Pseudomonas aeruginosa | Gram − | > 5.0 | > 99.999% | 20LA05885 |
| Enterococcus hirae | Gram + | > 5.0 | > 99.999% | 20LA05887 |
| Acinetobacter baumannii | Gram − | > 4.1 | > 99.992% | 20LA05886 |
| Staphylococcus aureus | Gram + | > 3.8 | > 99.984% | 20LA05883 |
| MRSA (methicillin-resistant S. aureus) | Gram + | > 3.5 | > 99.968% | 20LA05884 |
HACCP — coatings for environments where food is present (UNI 11021:2002)
Test report No. 372231 (16 June 2020) by Istituto Giordano S.p.A.: performance testing of a coating intended for environments where food is present, per UNI 11021:2002 and Italy's HACCP framework (D.Lgs. 193/2007). The manufacturer's signed declaration, included in the download, applies this report to New Atriapol. The report verifies:
- Anti-mould action at elevated humidity — no growth (score 0) of Aspergillus niger or Penicillium spp. under the high-humidity condition
- Washability — 5,000 cycles, meeting the ≥ 5,000-cycle requirement
- Resistance to cleaning and disinfection agents — no alteration after 24 h immersion in an active-chlorine detergent, an alkaline degreaser, an acid descaler, and a disinfectant (blistering 0 · cracking 0 · flaking 0)
- Dirt pick-up ΔL < 1 (limit ≤ 3.0) and odour transfer < 1 (limit ≤ 1)
This is the cleanability documentation for the New Atriapol finish that restaurants, cafés, and food-service fit-outs ask about.
HACCP / UNI 11021:2002 test report No. 372231 — Istituto Giordano S.p.A.
Italian original + Polish and English translations + manufacturer's declaration
The manufacturer
Colorificio Atria S.r.l. has manufactured coatings in Partanna, Sicily since 1968. The company operates under ISO 9001:2015 (quality) and ISO 14001:2015 (environmental) management systems and holds ReMade in Italy® certificate #1271/001 (Bureau Veritas). The complete certifications package below reproduces the stamped source documents in full.
Safety Data Sheets
English safety data sheets translated from the manufacturer's official Italian SDS, in the EU REACH/CLP structure — the revision date is shown on each sheet. Every sheet carries the ATRIA USA distributor block and a translation notice. Sheets not yet listed here, and the Italian originals, are available on request.
Atriafloor Primer BC
Safety Data Sheet (EN) · Rev. 3 · 2025
Atriafloor Rasante One
Safety Data Sheet (EN) · Rev. 4 · 2018
Atriafloor Stucco BC
Safety Data Sheet (EN) · Rev. 1 · 2019
Atriafloor Resina One
Safety Data Sheet (EN) · Rev. 10 · 2018
Atriafloor Consolidante
Safety Data Sheet (EN) · Rev. 4 · 2019
SuperTitanium BC
Safety Data Sheet (EN) · Rev. 4 · 2024
Titanium
Safety Data Sheet (EN) · Rev. 3 · 2019
Cementius
Safety Data Sheet (EN) · Rev. 6 · 2024
Glam Stone
Safety Data Sheet (EN) · Rev. 1 · 2025
Grace
Safety Data Sheet (EN) · Rev. 5 · 2018
Metallicum (Steel · Copper · Brass · Gold)
Safety Data Sheet (EN) · Rev. 6 · 2025
Nicole
Safety Data Sheet (EN) · Rev. 2 · 2025
Sofia
Safety Data Sheet (EN) · Rev. 4 · 2025
Silicatria Fondo
Safety Data Sheet (EN) · Rev. 1 · 2025
Silicatria Pittura
Safety Data Sheet (EN) · Rev. 1 · 2025
Silicatria Rivestimento
Safety Data Sheet (EN) · Rev. 1 · 2025
Traspirex
Safety Data Sheet (EN) · Rev. 3 · 2025
Wild Rust (Iron · Copper base)
Safety Data Sheet (EN) · Rev. 5 · 2025
Wild Rust Activator
Safety Data Sheet (EN) · Rev. 2 · 2025
Wild Rust Protective Sealer
Safety Data Sheet (EN) · Rev. 2 · 2025
Technical Data Sheets
Technical data sheets — coverage rates, application conditions, and cured-system data — are published on each product family page:
Need a document that isn't here — an original Italian SDS, additional test documentation, or specification support? Write to sales@atria-usa.com.